5.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑ Engine is stopped and starting disabled.
Putting into operation
Item
Lube oil system
Coolant circuit
Coolant circuit
Engine Control System
LOP
ECU
EIM
EMU 8
Exhaust gas aftertreatment
(SCR system)
Action
Check engine oil level (→ Page 203);
Preheat engine oil as necessary.
Check coolant level (→ Page 242).
Heat engine coolant with coolant preheater.
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 59).
Press illuminated pushbutton LAMP TEST (→ Page 59).
Check plug connections (→ Page 270).
Check plug connections (→ Page 272).
Check plug connections (→ Page 271).
Check urea solution system for leaks.
Check that seal on dosing unit is gas-tight.
Check electrical plug connections on DCM and urea solution components
(→ Page 35).
MS150123/01E 2017-05 | Operation | 61