8.
Faulty alignment motor
Cause
Alignment plate home
position sensor (PI6)
Wiring
Alignment plate
Alignment motor (M3)
Finisher controller PCB
9.
Faulty staple motor
Cause
Wiring
Stapler
Finisher controller PCB
Step
Checks
1
Check the alignment plate
home position sensor. Is it
normal?
2
Is the wiring between the
finisher controller PCB and
the alignment plate motor
normal?
3
Is there any mechanical
obstacle in the path of the
alignment plate?
4
Replace the alignment motor.
Is the problem corrected?
Step
Checks
1
Is the wiring between the
stapler and the finisher
controller PCB normal?
2
Replace the stapler. Is the
problem corrected?
CHAPTER 6 TROUBLESHOOTING
Yes/No
No
Replace the sensor.
No
Correct the wiring.
Yes
Remove the
mechanical obstacle.
Yes
End.
No
Replace the finisher
controller PCB.
Yes/No
No
Correct the wiring.
Yes
End.
No
Replace the finisher
controller PCB.
Action
Action