3.
Faulty height sensor (communication)
Cause
Finisher controller PCB
Wiring
Power supply
Height sensor (PS1)
4.
Faulty height sensor (disconnection)
Cause
Connector
Power supply
Height sensor (PS1)
Wiring
Step
Checks
1
Turn the host machine OFF
then ON. Is the problem
corrected?
2
Is the wiring between the
finisher controller PCB and
the sensors normal?
3
Measure the voltage between
J6-2 (+) and J6-4 (−) on the
finisher controller PCB. Is it 5
VDC?
Step
Checks
1
Is J6 on the finisher controller
PCB, J114 on the height
sensor, or the relay connector
J212 or J213 disconnected?
2
Measure the voltage between
J6-2 (+) and J6-4 (−) on the
finisher controller PCB. Is it 5
VDC?
3
Is the wiring between the
finisher controller PCB and
sensors normal?
CHAPTER 6 TROUBLESHOOTING
Yes/No
Yes
End.
No
Correct the wiring.
No
Replace the finisher
controller PCB.
Yes
Adjust the height
sensor once again. If
an error occurs again,
replace the height
sensor.
Yes/No
Yes
Connect the connector.
No
Replace the finisher
controller PCB.
Yes
Replace the height
sensor.
No
Correct the wiring.
Action