SAFETY

Read this First

Follow the instructions in this manual. These instructions are key to the installation and maintenance of the
Enphase IQ Envoy™.
To ensure the safe installation and operation of the IQ Envoy, note the following safety symbols that appear
throughout this document to indicate dangerous conditions and important safety instructions.
DANGER:
WARNING:
NOTE:

Safety Instructions

DANGER:
Risk of
electrocution!
DANGER:
Risk of electric
shock. Risk of
fire.
DANGER:
Risk of electric
shock.
WARNINGS:
NOTES:
5
This indicates a hazardous situation, which if not avoided, will result in death or serious injury.
This indicates a situation where failure to follow instructions may be a safety hazard or cause
equipment malfunction. Use extreme caution and follow instructions carefully.
This indicates information that is very important for optimal system operation. Follow instructions
carefully.
Do not install current transformers (CTs) when current is flowing in the sensed circuit. Always
install CT wires in the terminal blocks before energizing the sensed circuit.
Do not attempt to repair the IQ Envoy; it contains no user-serviceable parts. Tampering with or
opening the IQ Envoy will void the warranty. If the IQ Envoy fails, contact Enphase Customer
Support for assistance at enphase.com/en-us/support/contact. Refer servicing to qualified
personnel.
Only qualified personnel should troubleshoot, install, or replace the IQ Envoy.
Do not wire unused terminals or terminal blocks on the IQ Envoy.
Do not use Enphase equipment in a manner not specified by the manufacturer. Doing so may
cause death or injury to persons, or damage to equipment.
Always open or disconnect circuit from power-distribution system (or service) of building before
installing or servicing current transformers (CTs).
Before installing or using the IQ Envoy, read all instructions and cautionary markings in the
technical description and on the IQ Envoy.
Risk of equipment damage. When installing the IQ Envoy in an enclosure, choose area for
installation where ambient temperature does not exceed 46º C (115º F).
Do not install the CTs in a panel where they exceed 75% of the wiring space of any cross-sectional
area within the panel, or refer to local standards for guidance.
Do not install CTs in an area where they will block ventilation openings, or in area of breaker arc
venting.
The CTs are not suitable for Class 2 wiring methods and not intended for connection to Class 2
equipment.
Secure CT and route conductors so that they do not directly contact live terminals or bus.
Perform all electrical installations in accordance with all national and local electrical codes.
To ensure optimal reliability and to meet warranty requirements, the Enphase IQ Envoy must be
installed according to the instructions in this manual.