Technical Data - enphase IQ Envoy Installation And Operation Manual

Table of Contents

Advertisement

Technical Data

Model Numbers
IQ Envoy
ENV-IQ-AM1-240
Accessories (order separately)
Enphase Mobile Connect
[Enphase CELLMODEM-01 (3G) or
CELLMODEM-03 (4G)]
Consumption Monitoring CT
CT-200-SPLIT
Wire / Power Requirements / Specifications
Power requirements
Relay contacts
CT leads
Capacity
Number of microinverters polled
Mechanical Data
Dimensions (WxHxD)
Weight
Environmental Data
Ambient temperature range
Relative Humidity
Environmental rating
Altitude use
Cooling
44
Enphase IQ Envoy communications gateway with integrated revenue-grade PV
production metering (ANSI C12.20 +/- 0.5%) and optional consumption monitoring
(+/- 2.5%).
Plug and play industrial grade cellular modem with five-year data plan for systems
up to 60 microinverters. (Available where there is adequate cellular service in the
installation area.)
Split-core current transformers enable whole home consumption metering (+/- 2.5%).
120/240 VAC or 208Y/120 VAC, 0.22 A, 60 Hz, OVC III.
When hard wired and installed in an enclosure, the supply wiring must be 14 AWG
copper rated to 75 degrees C or better, and it must be protected by a maximum 15 A
breaker
240 VAC, OVC II
Pilot duty, B300 (240 V or 120 V, 360 VA)
The production CT leads are 1.5m (4.9') long, 18AWG, and are rated for 200A
The consumption CT leads are 4m (13.1') long, 18AWG, and are rated for 200A
Up to 600
21.3 x 12.6 x 4.5 cm (8.4" x 5" x 1.8")
17.6 oz. (498 g)
-40° to 65° C (-40° to 149° F)
-40° to 46° C (-40° to 115° F) if installed in an enclosure
95%
IP30. For installation indoors or in an NRTL-certified, NEMA type 3R enclosure
To 2000 meters (6560 feet)
Natural convection
© 2017 Enphase Energy Inc.
IQ Envoy Installation and Operation
141-00039 Rev 01