Led Behavior At Initial Start Up; Initial Communications Check; More About Device Communications States; Initiate A New Scan For Microinverters - enphase IQ Envoy Installation And Operation Manual

Table of Contents

Advertisement

LED Behavior at Initial Start Up

When the IQ Envoy starts up for the first time, it goes through the initial boot sequence. During this initial
boot sequence, all the IQ Envoy LEDs flash amber. Soon after connecting to the Internet, the IQ Envoy may
retrieve a software update, and the LEDs flash green sequentially during the update.
WARNING! Risk of Equipment Damage. Do not remove power from the IQ Envoy if the LEDs
are flashing green sequentially. This indicates that a software update is in progress.

Initial Communications Check

The IQ Envoy normally indicates no Internet connection for two to three minutes after the first start up. It
then sends the first report to Enlighten. When Enlighten responds, the Network Communications LED
lights solid green, indicating an Internet connection to Enlighten.

More about Device Communications States

A detected device (microinverter or battery) is one that has been discovered via the Envoy's device scan or
provisioned via Installer Toolkit or Enlighten.
The states of the Device Communications LED
the installer has provided an expected number of microinverters. If you have NOT provided the expected
number of microinverters either through the Activation form or in Installer Toolkit, the LED displays as
described in the No expected number provided column. If you have provided the expected number of
microinverters in the Activation form or in Installer Toolkit, this LED displays as described in the Expected
number provided column. If the Envoy has been provisioned with the serial numbers of the microinverters,
this displays as described in the With provisioning column.
State
No expected number
provided
Solid Green
All discovered devices are
communicating.
Solid Amber
At least one of the
discovered devices is not
communicating.

Initiate a New Scan for Microinverters

The IQ Envoy identifies each device by its unique serial number. If you add more microinverters to an existing
system or replace a microinverter or the IQ Envoy, you can run a scan to detect the new devices. To initiate a
scan after you add new microinverters to an existing Enphase system, perform the following steps.
Press the Device Scan button. The IQ Envoy begins a 15-minute scan to identify all of the
C.
microinverters deployed at the site. The Device Communications LED
the scan. Alternatively, you can initiate a scan using Installer Toolkit.
E. Log into Enlighten to check for the new microinverter, and use Array Builder to add the new
microinverter to the virtual array.
F. After the microinverter is detected, it is best to disable the scan. To do this, press the IQ Envoy
Device Scan button again.
24
have slightly different meanings, depending on whether
Expected number provided
The expected number of devices
was discovered and all are
communicating.
The number of devices
communicating is not equal to the
number expected (e.g., 0/12, 1/12,
11/12, or 13/12).
© 2017 Enphase Energy Inc.
IQ Envoy Installation and Operation
With provisioning
All of the provisioned devices are
communicating.
The devices that are
communicating are not the same
as those provisioned.
flashes green during
141-00039 Rev 01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents