DATA AND FIRMWARE DOWNLOAD/UPLOAD

6.9.4 FCU SRAM BACKUP (MACHINE TO IC CARD)

This makes a backup SRAM data (customer's programmed data) from the machine
to an IC card.
1. Turn off the main power. Insert the IC card into the IC card slot on the front of
the machine (left side).
NOTE: The FCU switch must be off.
2. Turn on the power and select "2. RAM (MACHINE → ROM)" and press START.
NOTE: The LCD display should be "MACHINE → FLASH ROM".
3. If "OK" is displayed, exit the function and turn the power off.
If "NG!!" is displayed, repeat from step 2.
4. Remove the IC card, insert the function upgrade card or FOD card (if it was
installed), and replace the cover.
6.9.5 OPTIONAL G3 UNIT CONTROL PROGRAM DOWNLOAD (IC
CARD TO MACHINE)
This updates the optional G3 unit control program (downloads it from an IC card).
1. After turning off the main power, insert the IC card containing the optional G3
unit program into the IC card slot on the front of the machine (left side).
NOTE: The FCU switch must be off.
2. Turn on the power and select "5. SG3 ROM" and press START.
NOTE: The LCD display should be "FLASH ROM → MACHINE".
3. If "OK" is displayed, exit the function and turn the power off.
If "NG!!" is displayed, repeat from step 2.
4. Remove the IC card, insert the function upgrade card or FOD card (if it was
installed), and replace the cover.
5. After turning the power back on, print out the system parameter list and check
that the program has been successfully downloaded.
6-42