November 29, 1999
6.2.7 REMOVING THE STAMP UNIT
1. With the ADF open, remove the ADF lower unit [A] (5 screws, 1 connector, 1
grounding wire).
2. Replace the stamp unit [B] (1 screw).
NOTE: When removing the stamp unit, ensure that ink does not leak out of it.
6.2.8 ADJUSTING THE SCANNING TOP MARGIN
To adjust the scanner home position, change the following RAM data. When the
value is increased (with respect to the default value), the image on the printed copy
moves down the page.
Address: 481246 default value: 18H
Adjustable range:
[B]
00 to 40H
6-11
ADF/SCANNER SECTIONS
H306R902.WMF
Unit: 0.5mm
[A]