PAPER FEED AND REGISTRATION
6.5.3 ADJUSTING THE PRINTING TOP MARGIN
Adjust the start position at the top of the page when the offset is large. The
procedure is as follows:
1. Make copies using the mainframe cassette, bypass unit, and optional feed units
and check the amount that the image is shifted.
2. Adjust by changing the contents of the following addresses:
Source
Main Frame
1st Optional Unit
2nd Optional Unit
By-pass Unit
3. To lower the start position, increase the default value.
To raise the start position, reduce the default value.
For example:
• To lower the start position by 2 mm (with respect to the default value):
1AH + ( 2 / 0.25 ) H = 22H
Address
480B00
480B01
480B02
480B06
6-20
Default
1AH
0.25 mm
1AH
0.25 mm
1AH
0.25 mm
1AH
0.25 mm
November 29, 1999
Unit