November 29, 1999
3.4.9 COUNTER TYPE 100
1. Remove the top cover [A] (2 screws) and right
cover [B] (4 screws).
2. Cut away the small cover [C] as shown.
3. Attach the counter [D] to the machine, then
connect cable [E] to the white connector [F].
4. Replace the top and the right covers.
5. Make some copies and check whether the counter works or not. If it doesn't,
check the cable connection from the counter to the FCU.
End of Procedure
INSTALLING OPTIONAL UNITS
H165I501.WMF
[C]
3-27
H165I502.WMF
[F]
[E]
H165I503.WMF
[D]
[A]
[B]