Starter For Auxiliary Motor Fan (Options +M602; What The Option Contains; Description - ABB ACS880-37 Hardware Manual

160 to 3200 kw
Hide thumbs Also See for ACS880-37:
Table of Contents

Advertisement

Starter for auxiliary motor fan (options +M602...+M610)

What the option contains

The option provides switched and protected connections for 3-phase auxiliary motor fans.
Each fan connection is equipped with
fuses
a manual motor starter switch with an adjustable current limit
a contactor controlled by the drive, and
terminal block X601 for customer connections.
The number of connections must be specified when ordering. The maximum number of
connections available depends on the current requirement. The lower current ratings allow
up to four fan connections (eg. option +4M602), while the highest current rating only allows
one (eg. +M610). For more information, refer to ACS880-X7 single drives ordering
information (3AXD10000052815, available on request).

Description

The output for the auxiliary fan is wired from the 3-phase supply voltage to terminal block
X601 through a motor starter switch and a contactor. The contactor is operated by the
drive. The 230 V AC control circuit is wired through a jumper on the terminal block; the
jumper can be replaced by an external control circuit.
The starter switch has an adjustable trip current limit, and can be opened to permanently
switch the fan off.
The statuses of both the starter switch and the fan contactor are wired to the terminal
block.
See the circuit diagrams delivered with the drive for the actual wiring.
Operation principle and hardware description 53

Advertisement

Table of Contents
loading

Table of Contents