Fuses On Cvar Varistor Board; Brake Chopper Dc Fuses; Dimensions And Weights; Free Space Requirements - ABB ACS880-37 Hardware Manual

160 to 3200 kw
Hide thumbs Also See for ACS880-37:
Table of Contents

Advertisement

186 Technical data

Fuses on CVAR varistor board

The CVAR board is used in units for UL and CSA installations.
The fuse type is Ferraz A070GRB10T13/G330010 (10 A 700 V AC).

Brake chopper DC fuses

Optional (+D150) brake choppers have two DC fuses each.
The fuse type is Bussmann 170M8635 (630 A 1000 V).

Dimensions and weights

See chapter
Dimensions

Free space requirements

The values are as required by cooling. Also obey the general installation rules given under
Fastening the cabinet to the floor and wall or roof (non-marine units)
Front
mm
150
*Measured from the base plate of the cabinet top.
> 400 mm (15.75 in.)
(page 201).
in.
mm
5.91
0
Sides
in.
0
(page 67).
Above*
mm
in.
400
15.75

Advertisement