PARTS REMOVAL FOR CLEANING/SANITIZING

Disconnect electric power to the ice machine at the
electric switch box and wear rubber gloves and safety
goggles (or face shield) while handling cleaner or
sanitizer.
NOTE: Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use these
solutions in a manner inconsistent with their labeling.
1. Turn off the water supply to the ice machine at the
water service valve.
2. Remove the components listed on the following
pages for cleaning and sanitizing.
3. Soak the removed part(s) in a properly mixed
solution of cleaner and water.
Solution Type
Cleaner
4. Use a soft-bristle brush or sponge (NOT a wire brush)
to carefully clean the parts.
5. Use the solution and a brush or sponge to clean all
disassembled components and the inside of the bin.
6. Rinse all cleaned parts with clear water.
7. Mix a solution of sanitizer and water.
Solution Type
Sanitizer
8. Soak the parts in the sanitizer/water solution for
10 minutes. Use the sanitizer/water solution and a
sponge to sanitize all removed components and the
inside of the bin. Do not rinse the sanitized parts.
9. Continue with step 11 of the cleaning/sanitizing
procedure.
32
Warning
n
Water
1 gal. (4 L)
Water
3 gal. (11 L)
Part Number 000007661 11/16
Mixed With
16 oz (500 ml) cleaner
Part Number 000000084
Mixed With
2 oz (60 ml) sanitizer