Summary of Contents for Manitowoc RF-0244

  • Page 1 Manitowoc Flake Ice Machine Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocice.com America’s #1 Selling Ice Machine Part Number 000005653 10/09...
  • Page 2: Table Of Contents

    Manitowoc Cleaner and Sanitizer ........
  • Page 3: Model Numbers

    Model Self-Storage Modular from that of original manufactured specifications. RF-0244 RF-0266 This appliance is not intended for use by persons (including children) with reduced physical, sensory RF-0388 or mental capabilities, or lack of experience and...
  • Page 4: Location Of Ice Machine

    B970 bins. RF-2300 ice machines ship with a CLEARANCE REQUIREMENTS bracket that must be used when installing on B1100 and B1400 Series bins. RF-0244 RF-0266 Air-Cooled Water-Cooled 1. Refer to diagram. Place bracket on bin top and slide RF-0388 back to engage.
  • Page 5: Water And Drain Requirements

    If water pressure exceeds the maximum of 80 psig Condenser 1/2" FPT (6 bar) recommended pressure, obtain a water Water pressure regulator from your Manitowoc distributor. Drain • Install a water shut-off valve and union for both the Bin Drain 3/4"...
  • Page 6: Electrical Requirements

    Phase/ Fuse/Circuit Circuit Circuit Fuse/Circuit Circuit Circuit Cycle Breaker Amps Amps Breaker Amps Amps 115/1/60 15 Amp RF-0244 230/1/50 10 Amp 115/1/60 15 Amp RF-0266 230/1/50 10 Amp 115/1/60 15 Amp 10.0 RF-0388 230/1/50 10 Amp 115/1/60 15 Amp 10.0...
  • Page 7: Evaporator Low Temperature Safety Thermostat And Bin Thermostat

    INCORRECT SETTINGS WILL CAUSE ICE MACHINE TO SHUT OFF The ice machine will not start until: RF-0244/RF0266/RF-0388/RF0399 Operation A. The rocker switch is moved to “ON”. The ice machine will not start until: B. Ice does not contact the bin thermostat bulb.
  • Page 8: Interior Cleaning And Sanitizing

    Use Ice Machine Sanitizer part number 94-0565-3. ! Caution Step 1 Remove front and top covers and set the toggle Use only Manitowoc approved Nickel Safe Ice switch to the OFF position. Machine Cleaner (part number 000000084) and Step 2 Remove all ice from the bin.
  • Page 9: Procedure To Clean Heavily Scaled Flake Ice Machines

    Water cleaner, part number Model Reservoir 000000084 only Capacity Cleaner Water RF-0244 RF-0266 Step 11 Reassemble ice machine. 14 oz (400 ml) 9 oz (266 ml) 5 oz (148 ml) RF-388 Step 12 Turn off the ice making water supply.
  • Page 10: Removal Of Parts For Cleaning/Sanitizing

    Maintenance Section 4 Removal of Parts for Cleaning/Sanitizing ICE CHUTE REMOVAL RF-0300/RF-0650/RF-1200/RF-2300 O Warning 1. Place the toggle switch in the OFF position, turn off Disconnect electric power to the ice machine at the the water supply and disconnect electrical power to electric switch box and wear rubber gloves and the ice machine.
  • Page 11: Ice Chute Switch Actuator Removal

    Manitowoc Cleaner and Sanitizer Manitowoc Ice Machine Nickel Safe Cleaner is available in convenient 16 oz. (473 ml) bottles. Manitowoc Ice Machine Sanitizer is available in 16 oz. (473 ml) and 1 gal (3.78 L) bottles.
  • Page 12: Before Calling For Service Checklist

    Wait 10 minutes. 10 minute time delay has not expired. Bin thermostat is open. Adjust to a warmer setting; refer to Operation. RF-0244/RF-0266/RF-0388/RF0399 Adjust to colder setting; refer to Operation. RF-0300/RF-0650 Only. Low temperature safety switch is open. RF-1200/RF-2300 Only.
  • Page 13: Commercial Ice Machine Warranty

    LIMITED WARRANTY The preceding paragraphs set forth the exclusive remedy for all Manitowoc Ice a division of Manitowoc FSG Services, LLC, claims based on failure of, or defect in, RF Flake Ice Machines sold (“Company”) warrants that new RF Flake Ice Machines sold by...
  • Page 14: Residential Ice Machine Limited Warranty

    Product at Manitowoc’s cost, including standard straight time labor charges, (2) replace the Product with one that In No Event Shall Manitowoc Or Any Of Its Affiliates Be is new or at least as functionally equivalent as the Liable To The Consumer Or Any Other Person For Any original, or (3) refund the purchase price for the Product.
  • Page 15: C Model Bin Limited Warranty

    LIMITED WARRANTY The preceding paragraphs set forth the exclusive remedy for all Manitowoc Ice a division of Manitowoc FSG Services, LLC, claims based on failure of, or defect in, C200, C350 Ice Storage Bins (“Company”) warrants that new C200, C350 Ice Storage Bins sold by...
  • Page 16 © 2009 Manitowoc Continuing product improvements may necessitate change of specifications without notice. Part Number 000005653 10/09 Manitowoc Manitowoc Foodservice 2110 South 26th Street, P.O. Box 1720 Manitowoc, WI 54221-1720, USA Ph: 920-682-0161 Fax: 920-683-7589 Visit us online at: www.manitowocice.com...