Manitowoc RNS0244 Technician's Handbook page 28

Flake & nugget ice machine r series
Table of Contents

Advertisement

Procedure to Clean/Sanitize
Use Ice Machine Cleaner part number 000000084.
Use Ice Machine Sanitizer part number 9405653.
Step 1
Remove front and top covers and set the
toggle switch to the OFF position.
Step 2
Remove all ice from the bin.
Step 3
Turn off the ice making water supply and drain
water from evaporator and reservoir.
Step 4
Remove the top cover from water reservoir.
Step 5
Follow the chart and premix cleaner and water.
Amount of Water
1 gallon (4 Liters)
Step 6
Fill the evaporator and reservoir with cleaning
solution.
28
Part Number 000000084
Prop Float Up to Prevent Low
Water Level Shutdown
Part Number 000007661 11/16
Amount of Cleaner
3 ounces (90 ml)