PARTS REMOVAL FOR CLEANING/SANITIZING

Single Evaporator Ice Machines.
A
B
A. Remove the water curtain
Gently flex the curtain in the center and remove it
from the right side.
Slide the left pin out.
B. Remove the water trough
Depress tabs on right and left side of the water
trough.
Allow front of water trough to drop as you pull
forward to disengage the rear pins.
C. Remove the water level probe
Pull the water level probe straight down to
disengage.
Lower the water level probe until the wiring
connector is visible.
Disconnect the wire lead from the water level
probe.
Remove the water level probe from the ice
machine.
50
D
C
E
Part Number STH026 2/12