CLEANING SANITIZING PROCEDURE RN0400
Use Ice Machine Cleaner part number 000000084.
Use Ice Machine Sanitizer part number 94-0565-3.
Step 1
Disconnect power, remove front, top and right
panels and set the compressor rocker switch to the OFF
position.
Step 2
Remove all ice from the bin/dispenser.
Step 3
Turn off the ice making water supply.
Step 4
Drain water from evaporator and reservoir
through the evaporator/reservoir drain line and reinsert
hose into hose clip.
Step 5
Follow the chart and premix cleaner and water.
Amount of Luke Warm
Water
1 gallon (4 Liters)
Step 6
Remove top cover from the water reservoir and
fill the evaporator and reservoir with cleaning solution.
Remainder of solution will be used for hand cleaning.
Step 7
Verify the compressor rocker switch is in the
OFF position, then reconnect power and run the gear
motor for 15 minutes. Perform the following procedures
during the 15 minute period:
•
Remove ice compression nozzle from evaporator and
soak in cleaning solution.
•
Descale drain pan by gently flexing, then remove any
scale residue.
•
Inspect water feed and drain lines and clean as
needed.
•
Connect ice transport tube direct to evaporator and
secure with hose clamp.
36
Amount of Cleaner
Part Number 000000084
4 ounces (120 ml)
Part Number 000007661 11/16
Need help?