CP03x/CP03xA Current Probes
Specifications
For the most current specifications, see the probe product pages at
teledynelecroy.com. Specifications are subject to change without notice.
Warranted Characteristics
Amplitude Accuracy
Bandwidth (probe only)
Nominal Characteristics
Max Continuous Input
Current at 0.1 V/A
Max Peak Current
Intended Output Load
Measured Conductors
Sensitivity *
Offset Range
(1x Attenuation)
Max Continuous Input
Current at 1 V/A
(100mA/div or less)
* Values are based on oscilloscopes with 1 mV/div sensitivity. Numbers will be higher on instruments with lower
sensitivity.
4
CP030/CP030-3M CP030A
±1.0 % of reading to 30 Arms
(45 to 65 Hz)
±2.0% of reading to 50 Apeak
DC to 50 MHz/10 MHz
CP030
CP030A
30 Arms
50 Apeak non-continuous
1 MΩ
Insulated Conductors only
10 mA/div to
1 mA/div to
15 A/div
15 A/div
N/A
±5 A
N/A
5 A
CP031
±1.0 % of reading to 30 Arms
(45 to 65 Hz)
±2.0% of reading to 50 Apeak
DC to 100 MHz
CP031
30 Arms
50 Apeak non-continuous
1 MΩ
Insulated conductors only
10 mA/div to
15 A/div
N/A
N/A
CP031A
CP031A
1 mA/div to
15 A/div
±5 A
5 A