Typical Characteristics
Output voltage
Sensitivity Temperature
Coefficient
Noise
Rise Time
Environmental Characteristics
Operating Temperature
Operating RH
Storage Temperature
Storage RH
Maximum Altitude
Effect of External
Magnetic Field
Physical Characteristics
Probe Head Length
Probe Head Width
Probe Head Height
Maximum diameter of
conductors measured
CP030/CP030-3M CP030A
0.1 V/A
0.1 V/A & 1 V/A
±2% or less (0⁰C to +40⁰C)
2.5 mArms or less 320 µArms
at Full BW
150 µArms
at 20 MHz BWL
≤ 7 ns / ≤ 35 ns
CP030
0 ⁰C to 40 ⁰C
CP030A
-10 ⁰C to 50 ⁰C
≤ 80% (non-condensing)
≤ 80% (non-condensing)
2000 m
Maximum of 20 mA in a DC/60 Hz,
400 A/m magnetic field
CP030
CP030A
175 mm (6.9 inch)
18 mm (0.7 inch)
40 mm (1.57 inch)
5 mm (0.2 inch)
Operator's Manual
CP031
0.1 V/A
±2% or less (0⁰C to +40⁰C)
2.5 mArms or less
≤ 3.5 ns
0 ⁰C to 40 ⁰C
CP031
-10 ⁰C to 50 ⁰C
≤ 80% (non-condensing)
≤ 80% (non-condensing)
2000 m
Maximum of 5 mA in a DC/60 Hz,
400 A/m magnetic field
CP031
175 mm (6.9 inch)
18 mm (0.7 inch)
40 mm (1.57 inch)
5 mm (0.2 inch)
CP031A
0.1 V/A & 1 V/A
320 µArms
at Full BW
150 µArms
at 20 MHz BWL
CP031A
CP031A
5