• Before using the probe for the first time, verify that it operates normally to ensure that no damage has
occurred during storage or shipping. If you find any damage, contact your dealer or a Teledyne LeCroy
representative.
• This device is not designed to be water or dust proof. To avoid damage, do not use it in a wet or dusty
environment.
• To avoid damaging the probe cable and power supply cable, do not excessively bend or pull the cables.
• When performing continuous measurements, it is necessary to be aware that the offset voltage may
drift, depending on factors such as the ambient temperature and probe temperature. If this happens
remove the probe from the DUT and peform a Auto Zero.
• Accurate measurements may be impossible in locations subject to strong external magnetic fields, such
as transformers and high-current conductors, or in locations subject to strong external electric or
magnetic fields, such as radio transmission equipment.

Accessories

1m BNC to BNC probe output connecting cable, to connect the T3CP100-2 BNC output to an
Oscilloscope input.
Wall socket PSU. The wall socket PSU can power the probe in place of the batteries.

Maintenance

Keep the probe dry and clean.
Clean the probe with a dry cloth, do not use liquid cleaning agents.
After use put the probe back in its case and store in a clean and dry place out of the sun.
To maintain the working life of the probe do not pull on, over twist or knot the connecting cable.

Specifications

T3CP100-2 Specifications
Current Range
Range Output
Oscilloscope Attenuation Ratio
Typical DC Precision
Bandwidth (-3dB)
Maximum Current Verses Frequency
Typical DC Linearity (High Range)
Rise Time
Phase Shift
Maximum Operating Current
Maximum Operating Voltage
Maximum Floating Voltage
Low Range
50mA - 10A Peak
35.35mA - 7.07A rms
0.1V/A
10:1
3% + 50mA
DC - 2MHz Refer to Figure 1
o
DC - 65Hz <1.5
Refer to Voltage And Current Rating Table
Refer to Voltage And Current Rating Table
Refer to Voltage And Current Rating Table
Page 7
High Range
1A - 100A Peak
0.707A - 70.7A rms
0.01V/A
100:1
500mA - 40A Peak: 4% + 50mA
40A - 100A Peak: + 15% Max
Refer to Figure 2
Refer to Figure 3
< 175ns
DC - 65Hz <1
o

Advertisement