Furuno BR-500 Operator's Manual page 64

Bridge navigational watch alarm system (bnwas)
Hide thumbs Also See for BR-500:
Table of Contents

Advertisement

APPENDIX 2 ALERT ICONS, IDS, MEANINGS AND MEASURES
AlertI/F1(2) mode alerts, IDs, meanings and measures
ID
Indication
1
250*
COM ERR with
Processor Unit
(220)001*
2
DC Power
Failure
2
(220)002*
AC Power
Failure
220003*
3
BNWAS Alarm
is 1st Stage
220004*
3
BNWAS Alarm
is 2nd Stage
3
220005*
BNWAS Alarm
is 3rd Stage
3
220950*
Communication
error with BAM
1
*
: This alert is displayed in three-digit format, regardless of selected alert mode.
2
*
: These alerts' ID is displayed in three-digit format for AlertI/F1 mode, six-digit
format for AlertI/F2 mode.
EG: 001 - Alert I/F1 mode
220001 - AlertI/F2 mode
3
*
: These alerts are displayed only when AlertI/F2 mode is active.
AP-4
Priority Category
Warning
B
Communication failure
between Processor Unit
and Main Alarm Panel
Warning
B
DC power to the unit is
interrupted or stopped.
Warning
B
AC power to the unit is
interrupted or stopped.
Alarm
A
Watch alarm is at first
stage
Alarm
A
Watch alarm is at
second stage
Alarm
A
Watch alarm is at third
stage
Caution
B
Communication failure
between Processor Unit
and Bridge Alert
Management (BAM)
system
Meaning
Consult a FURUNO
technician.
Check power to the
unit, check cabling
and connections to
the unit.
Check power to the
unit, check cabling
and connections to
the unit.
Press any key on the
Main Alarm Panel, or
press the Timer
Reset Panel button.
Press the RESET
key on the Main
Alarm Panel.
Press the RESET
key on the Main
Alarm Panel.
Check connection with
BAM system. Contact
FURUNO if the problem
is not resolved.
Measures

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents