4. INSTALLATION
4.7.6
How to fabricate cables for the Cabin Panel, Timer Reset Panel,
Flash Beacon and Motion Detector
Fabricate the above-mentioned cables as shown below.
Connect cores to
WAGO terminal block.
4.8

DIP Switch, Rotary Switch Settings

A DIP switch and a Rotary switch are provided in the Processor Unit to adjust the
equipment according to applicable regulations and ship's requirements.
Location of switches in the Processor Unit
DIP SW S1
ON
1 2 3 4 5 6 7 8
4-16
Sheath
Armor
Cut sheath.
Remove paint approx. 50 mm.
Vinyl
tape
L=Length between cable
clamp and terminal
Set this part
in cable clamp.
Rotary SW S2
SW position
Default setting in bold italic
Frequency
0
4.2 kHz
1
4.15 kHz
2
4.25 kHz
3
4.2 kHz
4
4.2 kHz
5
4.2 kHz
6
4.2 kHz
7
4.2 kHz
8
4.2 kHz
9
4.2 kHz
0
4.2 kHz
A
4.2 kHz
B
4.2 kHz
C
4.2 kHz
D
4.2 kHz
E
4.2 kHz
F
4.2 kHz