Operational Event Indications - Furuno BR-500 Operator's Manual

Bridge navigational watch alarm system (bnwas)
Hide thumbs Also See for BR-500:
Table of Contents

Advertisement

4. To close the [Active Alert] list and [Alert Log], press the MENU/ESC key.
Note 1: The [Alert Log] and [Active Alert] list are not available when there is a BNWAS
alert active. If a BNWAS alert is activated while the [Alert Log] or [Active Alert] list are
open, the menu is closed and the BNWAS display is restored.
Note 2: The help area at the bottom of the [Active Alert] list and [Alert Log] displays
the highest priority alert (currently active alert). If there is no active alert, this area
displays operational guidance.
1.9.3

Operational event indications

When an operational event occurs, the Main Alarm Panel shows the related message
in red, yellow or white in the help area.
MANUAL OFF
Autopilot OFF
PREWARNING WATCH ALARM
Push any key.
WATCH ALARM (1st Stage) Push
any key.
WATCH ALARM (2nd Stage) Push
[RESET] key to stop buzzer.
WATCH ALARM (3rd Stage) Push
[RESET] key to stop buzzer.
WATCH ALARM (2nd Stage: Emer-
gency Call) Push [RESET] key to
stop buzzer.
WATCH ALARM (3rd Stage: Emer-
gency Call) Push [RESET] key to
stop buzzer.
2nd Stage: External Emergency Call
Activated
3rd Stage: External Emergency Call
Activated
* RESET key not pressed or equipment on bridge is not operated.
Indication
Event
Manual Off mode selected.
Auto mode selected, Autopilot signal
off.
Presence on bridge* not confirmed
in dormant period.
Presence on bridge* not confirmed
at prewarning phase.
Presence on bridge* not confirmed
at 1st stage.
Presence on bridge* not confirmed
at 2nd stage.
Emergency call made from Main
Alarm Panel.
Emergency call made from Main
Alarm Panel.
Backup navigator signal received
Backup navigator signal received
1. MAIN ALARM PANEL
Color
White
White
Yellow
Red
Red
Red
Red
Red
Red
Red
1-11