Appendix 2 Alert Icons, Ids, Meanings And Measures - Furuno BR-500 Operator's Manual

Bridge navigational watch alarm system (bnwas)
Hide thumbs Also See for BR-500:
Table of Contents

Advertisement

APPENDIX 2 ALERT ICONS, IDS,
MEANINGS AND MEASURES
Alert icons and their attributes
Priority
Icon
level
Alarm
Active - unacknowledged
Alarm
Active - silenced
Alarm
Rectified - unacknowledged
Alarm
Active - responsibility
transferred
Alarm
Active - acknowledged
Warning
Active - unacknowledged
Warning
Active - silenced
Warning
Rectified - unacknowledged
Warning
Active - responsibility
transferred
Warning
Active - acknowledged
Caution
Active
Legacy mode alerts, IDs, meanings and measures
ID
Indication
010
Failure: Communication
011
Failure: AC
012
Failure: DC
Note: All Legacy mode alerts are assigned "Warning" level priority and alert category "B" rank.
Alert status
Meaning
Communication failure between
Processor Unit and Main Alarm
Panel
AC power to the unit is
interrupted or stopped.
DC power to the unit is
interrupted or stopped.
Displayed as
Red icon and indication
flashing at 0.5 second
intervals
Red icon and indication
flashing at 0.5 second
intervals
Red icon and indication
flashing at 0.5 second
intervals
Red icon and indication on
steadily
Red icon and indication on
steadily
Yellow-orange icon and
indication flashing at 0.5
second intervals
Yellow-orange icon and
indication flashing at 0.5
second intervals
Yellow-orange icon and
indication flashing at 0.5
second intervals
Yellow-orange icon and
indication on steadily
Yellow-orange icon and
indication on steadily
Yellow icon and indication
on steadily
Consult a FURUNO technician.
Check power to unit, check
cabling and connections to unit.
Check power to unit, check
cabling and connections to unit.
Audible alert
Three short beeps at
seven second
intervals.
OFF
OFF
OFF
OFF
Warning buzzer, two
short beeps at one
minute intervals.
OFF
OFF
OFF
OFF
OFF
Measures
AP-3