DIP Switch Setting

Configure the DIP switch before installing this unit.
Switch
Bit
Function
Left
1
Select
communication
mode
2 to 4 Select protocol
5 to 7 Set camera address For selecting a camera
8
Baud rate
Right
1
RS-232C,
RS-422/485
2
Remote control
infrared output
3 to 7 Service terminals
8
RS-422/485
termination
* Combination of bit and setting values of DIP switches 2 to 4 and 5 to 7
Setting Value (The following is for DIP switches 2 to 4. It is the same for DIP switches 5 to 7)
0
1
2
2 3 4
2 3 4
2 3 4
Bit
.
20
DIP Switch Setting
ON
1
2 3 4 5 6 7 8
.
Description
For selecting a
communication mode.
For selecting protocols.
address.
For selecting a baud rate
for serial communication.
For selecting a
communication terminal
for serial communication.
For selecting an infrared
output.
Set them to OFF during
use.
RS-485 receiving end 110
Ω termination
3
4
5
2 3 4
2 3 4
2 3 4
ON
1
2 3 4 5 6 7 8
OFF: LAN; ON: Serial
Setting values when LAN is set:
0: JVC; 1: D star; 2: Standard; 3 to 7:
Reserved
Setting values when Serial is set:
0: Reserved; 1: D star; 2: Standard; 3 to
7: Reserved
* For latest information on compatibility,
please visit our website.
Setting values when bit2 to bit 4 is set to
"Standard":
0: AUTO; 1 to 7: Cameras 1 to 7
OFF: 9600 bps, ON: 38400 bps
OFF: RS-232C; ON: RS-422/485
OFF: No output; ON: Outputs IR_OUT
from RS-232C IN terminal Directing the
infrared remote control that comes with
commercially available controllers
toward the camera allows you to operate
the commercially available controller
(connected via RS-232C).
-
OFF: Do not terminate; ON: Terminate
6
7
2 3 4
2 3 4
Remarks