Danfoss VLT AQUA FC 202 Operating Instructions Manual page 69

0.25-90 kw
Hide thumbs Also See for VLT AQUA FC 202:
Table of Contents

Advertisement

Specifications
525-600 V, Enclosure Types A, B, and C
Enclosure
Power [kW]
A2
1.1-4.0
A3
5.5-7.5
A5
1.1-7.5
B1
11-18
B2
22-30
B3
11-18.5
B4
22-37
C1
37-55
C2
75-90
C3
45-55
C4
75-90
Table 8.21 525-600 V, Enclosure Types A, B, and C
525-690 V, Enclosure Types A, B, and C
Enclosure
Power [kW]
1.1
1.5
2.2
A3
3
4
5.5
7.5
11
15
B2
18
22
30
37
C2
45
55
75
37
C3
45
Table 8.22 525-690 V, Enclosure Types A, B, and C
MG20MB02
Operating Instructions
Recommended
Recommended
fuse size
maximum fuse
gG-10
gG-10 (5.5)
gG-16 (7.5)
gG-10 (0.75-5.5)
gG-16 (7.5)
gG-25 (11)
gG-32 (15)
gG-40 (18.5)
gG-50 (22)
gG-63 (30)
gG-25 (11)
gG-32 (15)
gG-40 (18.5)
gG-50 (22)
gG-63 (30)
gG-63 (37)
gG-160 (37-45)
gG-100 (45)
aR-250 (55)
aR-160 (55)
aR-200 (75)
gG-63 (37)
gG-100 (45)
aR-160 (55)
aR-200 (75)
Recommended fuse size
gG-6
gG-6
gG-6
gG-10
gG-10
gG-16
gG-16
gG-25
gG-25
gG-32
gG-32
gG-40
gG-63
gG-63
gG-80
gG-100
gG-100
gG-125
Danfoss A/S © Rev. 05/2014 All rights reserved.
Recommended circuit
breaker
Moeller
gG-25
PKZM0-25
gG-32
PKZM0-25
gG-32
PKZM0-25
gG-80
PKZM4-63
gG-100
NZMB1-A100
gG-63
PKZM4-50
gG-125
NZMB1-A100
NZMB2-A200
aR-250
NZMB2-A250
gG-150
NZMB2-A200
aR-250
NZMB2-A250
Recommended
Recommended circuit
maximum fuse
breaker
Danfoss
gG-25
CTI25M 10-16
gG-25
CTI25M 10-16
gG-25
CTI25M 10-16
gG-25
CTI25M 10-16
gG-25
CTI25M 10-16
gG-25
CTI25M 10-16
gG-25
CTI25M 10-16
gG-63
gG-63
gG-80
gG-100
gG-125
gG-160
gG-125
gG-160
Maximum trip level
[A]
25
25
25
63
100
50
100
160
8
250
150
250
Maximum trip
level [A]
16
16
16
16
16
16
16
67
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents