APPEARANCE AND ODOR
Cream to white colored fiber shapes. With or without optional white to gray granular surface coating and/or
optional black surface coating.
SPECIFIC WEIGHT: 12-25 lb./cubic foot
VOLATILES (% BY WT.): N.A.
MATERIAL, QUANTITY, AND THRESHOLD/EXPOSURE LIMIT VALUES
Aluminosilicate (vitreous) 99+ %
CAS. No. 142844-00-06
Zirconium Silicate
Black Surface Coating**
Armorphous Silica/Silicon Dioxide
**Composition is a trade secret.
SECTION IV.
FLASH POINT:
None
EXTINGUISHING MEDIA
Use extinguishing agent suitable for type of surrounding fire.
UNUSUAL FIRE AND EXPLOSION HAZARDS / SPECIAL FIRE FIGHTING PROCEDURES
N.A.
P-6
SECTION II.
SECTION III.
HAZARDOUS INGREDIENTS
FIRE AND EXPLOSION DATA
PHYSICAL DATA
BOILING POINT: N.A.
WATER SOLUBILITY: N.A.
1 fiber/cc TWA
10 fibers/cc CL
0-10% 5 mg/cubic meter (TLV)
0 - 1% 5 mg/cubic meter (TLV)
0-10% 20 mppcf (6 mg/cubic meter)
PEL (OSHA 1978) 3 gm cubic meter
(Respirable dust): 10 mg/cubic meter,
Intended TLV (ACGIH 1984-85)