About Media Server Port Connections; S8700-Series Port Connections - Avaya S8700 Series Installing And Configuring

Hide thumbs Also See for S8700 Series:
Table of Contents

Advertisement

Chapter 1: Introduction
Environmental specifications for the S8710 and S8720 are shown in
.
Table 3: S8710/S8720 Media Server environmental specifications
Parameter
Air Temperature
Humidity
Electrical input
Power supply output

About media server port connections

The following section explains how to connect the Ethernet ports on the back of the media
server.

S8700-series port connections

The network cable connections depend on the type of memory duplication and the type of
control network. All cables are CAT5 or better patch cables except for the fiber cable that
interconnects the DAL1 or DAL2 cards for hardware duplication.
12
Installing and Configuring the Avaya S8700-Series Media Server
Description
Ambient operating: 50°F to 95°F (10°C to 35°C)
Maximum wet bulb: 82.4°F (28°C)
NOTE: All temperature ratings shown are for sea level. An altitude
derating of 1.8°F per 1000 ft to 10,000 ft (1°C per 300 meters) is
applicable. No direct sunlight is allowed.
Operating: 10% to 90%
Nonoperating: 5% to 85%
NOTE: The storage maximum humidity of 95% is based on a
maximum temperature of 113°F (45°C). The altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Rated input voltage: 100 VAC to 240 VAC
Rated input frequency: 50 Hz to 60 Hz
Rated input current: 6 A (110 V) to 3 A (220 V)
Rated input power: 600 W
BTUs per hour: 2050
Rated steady-state power: 400 W
Maximum peak power: 400 W
Table
3.
February 2007

Advertisement

Table of Contents
loading