Configuring/address space
4.4 Parameters
4.4.2
Parameters for operating with technology object "Counting and measurement"
Parameters of the TM Count 1x24V
The following parameter settings are possible:
Table 4- 5
Settable parameters and their default setting in "Operating with technology object "Counting and measure-
ment"" operating mode
Parameter
Operating mode
Sensor type
Reaction to CPU STOP
Enable diagnostic interrupt
on wire break
Enable additional diagnos-
tic interrupts
Signal type
Signal evaluation for coun-
ter inputs
36
Value range
Use counter value as reference
•
Use measured value as reference
•
Sourcing output
•
Sinking output
•
Push-pull (sinking and sourcing
•
output)
Output substitute value
•
Keep last value
•
Continue operation
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Pulse (A)
•
Pulse (A) and direction (B)
•
Count up (A), count down (B)
•
Incremental encoder (A, B phase-
•
shifted)
Incremental encoder (A, B, N)
•
Single
•
Double
•
Quadruple
•
Default setting
configura-
tion in RUN
Use counter value
No
as reference
Sourcing output
Yes
Output substitute
Yes
value
Deactivated
Yes
Deactivated
Yes
Pulse (A) and
Yes
direction (B)
Single
Yes
Technology Module TM Count 1x24V (6ES7138-6AA00-0BA0)
Manual, 02/2017, A5E33002339-AB
Re-
Effective range
with
configuring soft-
ware
HSP for STEP 7
(TIA Portal)
Channel
Channel
Channel
Channel
Channel
Channel
Channel