Siemens SIMATIC ET 200SP Manual page 38

Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Configuring/address space
4.4 Parameters
Parameter
Hardware interrupt: New
Capture value available
Hardware interrupt: Syn-
chronization of the counter
by an external signal
Set output
Substitute value for DQ
Count direction of the DQ
function
Pulse duration [ms/10]
Set function of DI
Select level for DI
38
Value range
Deactivated
Activated
Deactivated
Activated
Use by user program
Between comparison value and
high limit / measured value >=
comparison value
Between comparison value and
low limit / measured value <=
comparison value
At comparison value for a pulse
duration
After set command from CPU until
comparison value
Between comparison value 0
and 1
Not between comparison value 0
and 1
0
1
Forward
Backward
In both directions
0...65535
Gate start/stop (level-triggered)
Gate start (edge-triggered)
Gate stop (edge-triggered)
Synchronization
Enable synchronization at sig-
nal N
Capture
Digital input without function
Active with high level
Active with low level
Default setting
configura-
tion in RUN
Deactivated
Yes
Deactivated
Yes
DQ0, DQ1:
Yes
Between compari-
son value and
high limit
DQ0, DQ1: 0
Yes
In both directions
Yes
5000 (corre-
Yes
sponds to 0.5 s)
Yes
DI0: Gate
start/stop (lev-
el-triggered)
DI1: Digital
input without
function
DI2: Digital
input without
function
Active with high
Yes
level
Technology Module TM Count 1x24V (6ES7138-6AA00-0BA0)
Manual, 02/2017, A5E33002339-AB
Re-
Effective range
with
configuring soft-
ware
HSP for STEP 7
(TIA Portal)
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel