Martin Exterior Projection 1000 User Manual – Preliminary page 29

Table of Contents

Advertisement

2. See illustrations below. Use a 6 mm Allen key (hex wrench) to remove the eight top cover screws
(arrowed). Lift the top cover off the fixture. For ease of access – and if it is safe to do so – you can
unclip the safety cable and remove the cover completely from the fixture.
To reinstall the top cover:
1. See illustration on right. Check the silicone seal in
the top cover. If it is not in perfect condition,
replace it with a new item from Martin™.
2. If you unclipped the top cover safety cable,
reinstall the clip.
3. Reinstall the four top cover screws by first
inserting them finger-tight. Then use a torque
driver and cross-tighten the screws in a diagonal
pattern, increasing torque gradually in stages until
you reach a torque of 1.9 – 3.5 Nm.
4. Activate "Evaporation mode" under" Control
menus" so as to evaporate the air inside the fixture.
Exterior Projection 1000 User Manual
29

Advertisement

Table of Contents
loading

Table of Contents