Advertisement

Quick Links

Exterior Projection 1000
User Manual – Preliminary

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Exterior Projection 1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Martin Exterior Projection 1000

  • Page 1 Exterior Projection 1000 User Manual – Preliminary...
  • Page 2: Dimensions

    Martin™, Harman™ and all other trademarks in this document pertaining to services or products by Martin Professional™ or its affiliates and subsidiaries are registered as the property of Harman International Industries.
  • Page 3: Table Of Contents

    Table of contents Dimensions ........................2 Safety information ......................4 Introduction ........................7 Before using the product for the first time ................. 7 Fixture overview ........................ 8 Physical installation ......................9 Protection from the sun ....................9 Protection from moisture ....................9 Mounting the fixture......................
  • Page 4: Safety Information

    Martin™ website at http://www.martin.com. Martin™ user manual versions are identified by the Revision letter given at the bottom of page 2. Refer any operation not described in this user manual to Martin™ Global Service or an authorized Martin™ service agent.
  • Page 5 Isolate the fixture from power immediately if any seal, cover, cable, connector or other component is damaged, defective, deformed, wet or showing signs of overheating. Contact Martin™ for any service operation not described in this user manual. Do not reapply power until repairs have been completed Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for the electrical requirements of all connected devices.
  • Page 6 In the event of an operating problem, stop using the fixture immediately and disconnect it from power. Do not attempt to use a fixture that is obviously damaged. Do not modify the fixture or install other than genuine Martin™ parts. Exterior Projection 1000 User Manual...
  • Page 7: Introduction

    Introduction The Exterior Projection 1000 from Martin™ is an image projection fixture that combines a powerful 440 W LED engine, advanced dynamic effects and rugged weatherproofing. It has a zoom range from 10 - 43.5 degrees and is ideally suited to the projection of images and/or text such as logos.
  • Page 8: Fixture Overview

    Go down a menu branch UP (▲) Go up a menu branch ENTER Confirm the selected function 3. Adjustable mounting yoke 4. DMX data combined in/out cable 5. AC mains power cable 6. Pressure relief valve 7. Safety aperture Exterior Projection 1000 User Manual...
  • Page 9: Physical Installation

    Make sure that the sun will not shine into the front of the fixture at any time. The Glare Shield available from Martin™ can help protect the front of the fixture from the sun. If the control panel will be exposed to sunlight, install its cover to protect the panel and its display from heat and UV radiation.
  • Page 10: Avoiding Galvanic Corrosion

    Once pan is correct, fasten two 12 mm (1/2 inch) shaft diameter bolts to the surface with one bolt passing through each of the holes B. Once bolts have been installed in holes B, pan adjustment is no longer possible. Mounting yoke base Exterior Projection 1000 User Manual...
  • Page 11: Secondary Attachment

    See illustration on right. If you require very precise aiming and setup, we recommend that you order the projection setup gobo available from Martin™ for the Exterior Projection 1000 (see ’Accessories’ on page 36) and install it in the gobo wheel while you adjust fixture aim, focus, etc.
  • Page 12: Ac Power

    Do not try to connect to a three-phase three-wire (three phases, ground/earth) system. There is no power on/off switch. Power is applied to an Exterior Projection 1000 fixture as soon as it is connected to power. Provide a means to disconnect or shut down power to fixtures that is easily accessible and is located close to the fixtures.
  • Page 13 Follow the plug manufacturer’s instructions and connect the wires in the power cable as shown in the table below: Live or L Neutral or N Earth, Ground or US system Black White Green EU system Brown Blue Yellow/green Exterior Projection 1000 User Manual...
  • Page 14: Control Data Link

    If you connect one data output to more than one data input, you will split the DMX data link into branches which will probably cause data signal integrity problems. The Exterior Projection 1000 is supplied with a hard-wired 1.8 m (5.9 ft.) shielded cable with 2 pairs of wires for connection to a DMX data link.
  • Page 15 Signal DMX in + DMX in - DMX out + DMX out - common Male XLR pinout pin 3 pin 2 pin 1 Female XLR pinout pin 3 pin 2 pin 1 Data connection pinouts Exterior Projection 1000 User Manual...
  • Page 16: Fixture Setup

    The factory default user password is 111. The user password can be reset to any value from 0 to 999. Setting a DMX address The Exterior Projection 1000 uses twenty DMX channels to receive instructions from a DMX controller. The fixture’s DMX address, also known as the start channel, is the first of these channels. If a fixture that requires 4 DMX channels has its DMX address set to 1, for example, then it uses channels 1, 2, 3 and 4.
  • Page 17: Programming A Standalone Show

    The manual test commands let you display a single scene (i.e. a single combination of effects) manually, either for test purposes or to control the fixture without a DMX controller. To set up the scene: 1. Select MANUAL TEST and press ENTER. Exterior Projection 1000 User Manual...
  • Page 18: Display Setting

    3. Press ENTER to confirm. Display intensity To adjust the brightness of the control panel display: 1. Select INTENSITY and press ENTER. 2. Scroll to a value from 0 to 100%. 3. Press ENTER to confirm. Exterior Projection 1000 User Manual...
  • Page 19: Fixture Configuration (Including Master/Slave Operation)

    ENTER. Finally, press and hold MENU to exit the control menus. 5. Fixtures will now run standalone shows synchronized with the master fixture’s standalone shows whenever the fixtures are powered on and not receiving a DMX control signal. Exterior Projection 1000 User Manual...
  • Page 20: Fixture Status

    = 111) before you can access the FIXTURE OFFSET menu. Setup via RDM The Exterior Projection 1000 is compatible with RDM (Remote Device Management). Using an RDM-compliant DMX controller, you can communicate with all the fixtures on a data link without needing to access the fixture’s control panels or connect to each fixture individually.
  • Page 21: Effects

    The color wheel is shown below viewed from the LED side (rear of the fixture): Color wheel Slot 1: Deep Red Slot 2: Light Blue Slot 3: Primary Green Slot 4: CTO Slot 5: Orange Slot 6: CTB Slot 7: Violet Exterior Projection 1000 User Manual...
  • Page 22: Gobos

    As an alternative to the above colors, Martin™ can supply custom color filters made to special order. Please consult your Martin™ supplier for details. Gobos The fixture contains a rotating gobo wheel with the seven rotating glass gobos shown below, viewed...
  • Page 23: Animation Effect

    The position if the animation wheel can be adjusted on a separate DMX channel. This allows to modify the animation effect from a horizontal to a vertical effect. Exterior Projection 1000 User Manual...
  • Page 24 Animation Horizontal 90 Animation 62.5 (left) Exterior Projection 1000 User Manual...
  • Page 25: Prism

    The motorized focus lets you adjust the sharpness of projections from the controller. Gobo animation effects, for example, can be most effective if they are slightly out of focus. Zoom The motorized zoom let you adjust the beam angle from 10 - 43.5 Exterior Projection 1000 User Manual...
  • Page 26: Operation

    Important! Keep power applied at all times during periods when the temperature may fall below freezing point. The Exterior Projection 1000 is designed to operate at ambient temperatures between -30°C (-22° F) and 45° C (113° F), but whenever the ambient temperature falls below 0° C (32° F) power must remain applied constantly.
  • Page 27: Maintenance

    Read ‘Managing humidity’ below and follow the guidelines in this user manual carefully. Refer any service or repair operation not described in this manual to an authorized Martin™ service technician. Do not try to carry out such an operation yourself, as doing so may present a health or safety risk.
  • Page 28: Seals And Sealing Surfaces

    • Replace valves after an extended period of use. Intervals for valve replacement depend on the installation environment. • Consult your Martin™ dealer about a suitable valve replacement schedule. Contact Martin™ Service for valve replacement Removing and reinstalling the top cover Important! Open the fixture in dry weather conditions only.
  • Page 29 1. See illustration on right. Check the silicone seal in the top cover. If it is not in perfect condition, replace it with a new item from Martin™. 2. If you unclipped the top cover safety cable, reinstall the clip.
  • Page 30: Replacing A Rotating Gobo

    If you replace gobos, make sure that you always install this goboholder in its original position in slot 3. The rotating gobos in the Exterior Projection 1000 are installed in gobo holders that clip into the rotating gobo wheel.
  • Page 31 Always remove and reinstall gobo holders with alignment marks in the same position so that you keep gobos in the same orientation. 3. See illustration below. Pull the goboholder forwards, away from the wheel, then lift it up out of the wheel. Exterior Projection 1000 User Manual...
  • Page 32 Gobos 5 and 6 only Gobos 5 and 6 are structured glass and require a thrust washer. See illustration below. Place the black thrust washer (arrowed) over the gobo before you go on to the next step. Exterior Projection 1000 User Manual...
  • Page 33 If the goboholder does not rotate, it is not correctly installed and its teeth are probably not engaged correctly in the teeth in the gobowheel. Lift the goboholder out of the gobowheel and reinstall it correctly. Exterior Projection 1000 User Manual...
  • Page 34: Installing A Glare Shield Accessory

    Installing a glare shield accessory A glare shield is available as an optional accessory for the Exterior Projection 1000. The shield protects from stray light and can help protect the fixture from damage caused by the sun shining on the front of the fixture.
  • Page 35: Dmx Protocol

    Split Color 6/Color 7 Color 7 Split Color 7/Open 192-200 Open Stepped 201-203 Slot 1 204-206 Slot 2 207-209 Slot 3 210-212 Slot 4 213-215 Slot 5 216-218 Slot 6 219-221 Slot 7 222-255 Open Exterior Projection 1000 User Manual...
  • Page 36 No frost ->full frost Prism 0 - 5 Open 6-10 3-facet prism indexing 11 - 15 Linear prism indexing Snap 16 - 20 3-facet prism rotation 21 - 25 Linear prism rotation 26 - 255 No function Exterior Projection 1000 User Manual...
  • Page 37 40-44 Parameter shortcuts = ON (default) 45-49 Parameter shortcuts = OFF Snap 50-54 Auto-blackout = On 55-59 Auto-blackout = OFF (default) 60-64 Illuminate display on fixture 65-69 Turn off display on fixture 70-255 No function Exterior Projection 1000 User Manual...
  • Page 38: Control Menus

    0-255 Magenta 0-255 Yellow 0-255 Color Selection 0-200 Gobo Selection 0-74 Manual Manual test Gobo Ind/Rot 0-65535 mode Animation Index 0-255 Animation Rotation 0-255 Frost 0-255 Prism 0-25 Prism Rotation 0-255 Zoom 0-65535 Focus 0-65535 Exterior Projection 1000 User Manual...
  • Page 39 Yes/No Software Version 1.0.0 Cyan -128~127 Service Magenta -128~127 Adjust Yellow -128~127 Offset Color Selection -128~127 (Password Fixture 0…999) Gobo Selection -128~127 Offset (Super Gobo Ind/Rot -128~127 Password 111) Animation Index -128~127 Animation Rotation -128~127 Exterior Projection 1000 User Manual...
  • Page 40 Frost -128~127 3 Facet Prism -128~127 Line Prism -128~127 Prism Rotation -128~127 Zoom -128~127 Focus -128~127 0…999 Lid Open Lid Closes(15 minutes later) Evaporation mode Password (Super Password “Press 111) Enter” “Press Enter” Exterior Projection 1000 User Manual...
  • Page 41: Troubleshooting

    Attempt to control fixture with another DMX control device. Move or shield DMX link if it is close to an unshielded high-voltage installation. Contact your Martin authorized Internal fault. distributor or service center for assistance. Exterior Projection 1000 User Manual...
  • Page 42: Specifications

    Animation . Continuous effect, speed and direction, adjustable from vertical to horizontal (45°-156°) Zoom ..................Motorized, 16-bit fine and coarse control Shutter ..............Strobe and pulse effects, instant open and blackout Dimming ................0-100% constantly variable, 16-bit control Exterior Projection 1000 User Manual...
  • Page 43 LED lifetime ................ 20 000 hours (to >70% luminous output)* *Figure obtained under manufacturer's test conditions Photometric Data Luminous output ....................Up to 16800 lumens For full photometric data see www.martin.com Construction Housing ......................... Cast aluminum Color ..................Hard-anodized, metallic grey lacquered Front glass ............
  • Page 44 Minimum ambient temperature (Ta min) ..............-30°C (-22° F)* *Power must remain constantly applied in ambient temperatures below 0° C (32° F). Accessories Exterior Projection 1000 Glare Shield ................P/N 91611767 Exterior Projection 1000 Projection Setup Gobo ............P/N 91616068 Exterior Projection 1000 User Manual...
  • Page 49 · Olof Palmes Allé 18 · 8200 Aarhus N · Denmark Tel: +45 8740 0000 · Fax +45 8740 0010...

Table of Contents