Martin JEM ZR25 User Manual

Martin JEM ZR25 User Manual

Jem zr series
Hide thumbs Also See for JEM ZR25:

Advertisement

READ AND SAVE THESE INSTRUCTIONS
P/N 35010042-E

user manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JEM ZR25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Martin JEM ZR25

  • Page 1: User Manual

    READ AND SAVE THESE INSTRUCTIONS P/N 35010042-E user manual...
  • Page 2: Dimensions/Legal

    Dimensions/Legal All dimensions are in millimeters Dimensions/Legal...
  • Page 3 JEM™ are registered trademarks of ® ©2016 HARMAN Professional Denmark ApS. All rights reserved. Martin HARMAN Professional Denmark ApS registered in the United States and/or other countries. Features, specifications, and appearance are subject to change without notice.
  • Page 4: Table Of Contents

    Approved Fog Fluid types ......................20 Approved Discontinued Fluids: .................... 21 ZR45 Temperature Menu ..................... 21 Basic service ..........................22 Cleaning ..........................22 Martin Pro-Clean and Storage Fluid ..................22 Fuse replacement ........................ 23 Troubleshooting ........................24 Status messages ........................25 Technical Specifications ......................26...
  • Page 5: Safety Information

    If the machine or any cables connected to it are in any way damaged, defective, wet, or show signs of overheating, stop using the machine and contact Martin Service and Support for assistance. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
  • Page 6 Do not spill fluid over or inside the machine. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, take the machine out of service and contact Martin Service and Support for advice.
  • Page 7  Do not point fog output directly at a person’s face or at face height. For the latest user documentation and other information for this and all Martin products, please visit the Martin website at http://www.martin.com If you have any questions about how to install, operate or service the fixture safely, please contact your Martin distributor, dealer or contact Martin Service and Support.
  • Page 8: Product Overview

    P r o d u c t d e s c r i p t i o n The JEM ZR25, ZR35 and ZR45 provide a uniquely flexible and convenient solution to a wide range of fog requirements whether permanently installed or taken on the road.
  • Page 9: Product Details

    P r o d u c t d e t a i l s Hanging Bracket ZR25 Fluid Reservoir Fluid pipe connection Integrated Digital Remote Control DMX input Mains fuse and output Mains power Mains power switch connector If suspending overhead: Loop safety cable under hanging bracket and secure...
  • Page 10 ZR35 Hanging Bracket Fluid Reservoir Fluid pipe connection Integrated Digital Remote Control Mains power DMX input switch and output Mains fuse Mains power connector If suspending overhead: Loop safety cable under hanging bracket and secure Fog output nozzle WARNING! High temperature vapour and surfaces Product overview...
  • Page 11 ZR45 Hanging Bracket Fluid Reservoir Fluid pipe connection Integrated Digital Remote Control Mains power DMX input switch and output Mains fuse Mains power connector If suspending overhead: Loop safety cable under hanging bracket and secure Fog output nozzle WARNING! High temperature vapour and surfaces Product overview...
  • Page 12: Quick Start

    Locate the machine in a suitably large area with nothing in front of the fog output. Fill the fluid reservoir with an approved Martin fog fluid as shown on page 20. Connect a suitably rated power supply to the machine.
  • Page 13: Installation And Setting Up

    Installation and setting up DANGER! DO NOT operate the machine until you have read and observed all the precautions listed under “Safety information” on page 5. L o c a t i o n The JEM ZR series machines are designed to be located on the floor or may be suspended using the hanging bracket.
  • Page 14: Setting Up

    S e t t i n g u p Fill the fluid reservoir with an approved Martin fog fluid as shown on page 20. If DMX control is being used, connect the machine to the DMX line (see page 19).
  • Page 15: Control Settings

    Control settings O v e r v i e w The Integrated Digital Remote Control on the rear of the machine allows you to configure it using option menus. The Integrated Digital Remote Control may be removed from the machine and used at a distance by removing the two hand-wheel bolts either side of the display.
  • Page 16: Setting The Timer

    If you want to temporarily change the fog density, do not press ENTER. The fog setting will go back to its stored value next time the machine is powered up. This applies to all options. S e t t i n g t h e T i m e r The timer function can be utilized to set the machine’s output to automatically cycle between an 'On' time interval and an 'Off' time interval.
  • Page 17: Setting The Master-Slave Link Mode

    S e t t i n g t h e m a s t e r - s l a v e l i n k m o d e It is possible to control several machines from one digital remote control. The machine with the remote plugged into it is set as the Master.
  • Page 18 The factory settings are: option setting FOG LEVEL 50% TIMER ON 10 seconds TIMER OFF 20 seconds RUN MODE STANDBY 001 BACK LIGHT NORM LINK MODE RECEIVE PRIME NO TEMPERATURE* NORM *ZR45 Only Control settings...
  • Page 19: Dmx Control

    DMX control O v e r v i e w DMX is a digital control system widely used in entertainment and architectural lighting. Any controller meeting the DMX-512A standard may be used to control and program the fog output of the JEM ZR series machines. When a DMX signal is present, the JEM ZR series machine’s stand- alone functions do not work.
  • Page 20: Approved Fog Fluid Types

    Approved Fog Fluid types The JEM ZR series machines must only be used with the Martin fog fluids listed below. Martin supplies high quality fog fluids that are based on ultra-pure deionized water. No other fluid is suitable for use.
  • Page 21: Approved Discontinued Fluids

    DANGER! The JEM ZR series machines can run safely only on the specific fog fluids they are designed for. Use ONLY the Martin fog fluids designated in this manual. NEVER use any other type of fluid, or toxic gas may be produced. You will probably also cause damage to the machine that will invalidate the product warranty.
  • Page 22: Basic Service

    C l e a n i n g a n d P r e v e n t a t i v e M a i n t e n a n c e P r o c e d u r e : Use Martin Pro Clean and Storage Fluid after every 200 hours of operation or monthly depending on usage and duty cycle.
  • Page 23: Fuse Replacement

    120 V = 20 AT/125 V 230 V = T12.5 AT/250 V Replace fuse only with one of exactly the same size and rating. Contact Martin Service and Support if the fuse blows repeatedly. To replace the internal fuse, disconnect the power cord from the supply, unscrew the screws holding the top cover of the unit and remove the cover.
  • Page 24: Troubleshooting

    Troubleshooting Problem Probable cause(s) Suggested remedy Machine not at operating Wait until HEAT message temperature no longer shown Machine will not produce FOG option set to 0 Increase setting fog when remote control set Machine in timer mode and to CONTINUOUS or fog Increase setting TIMER ON set to 0 button pressed...
  • Page 25: Status Messages

    Run out of fluid. Refill the fluid reservoir and operate the FLUID OUT prime function in the SETTINGS menu The machine has detected an error with its calibration CALIBRATION settings and will not operate. Call Martin Service and ERROR Support. The machine has detected an error in the temperature SYSTEM sensor and will not operate.
  • Page 26: Technical Specifications

    Technical Specifications P h ys i c a l ZR25 Length ..................485 mm (19.1 in.) Width ................... 335 mm (13.2 in.) Height .................... 242 mm (9.6 in.) Height with hanging bracket ............333mm (13.2 in.) Weight, dry ................... 11.2 kg (24.7 lb.) Weight, filled .................
  • Page 27 C o n s t r u c t i o n Housing ..................Steel & aluminum Hanging bracket ....... Integrated yoke with safety attachment point Color ....................... Black Heat exchanger, ZR25 ..........1150 W, thermally protected Heat exchanger, ZR35 ..........1500 W, thermally protected Heat exchanger, ZR45 EU .........
  • Page 28 2 m (6.6 ft.) ..................P/N 11501046 A c c e s s o r i e s JEM ZR25 Ducting System, with 5 m (16.4 ft.) ducting ....P/N 92625012 JEM ZR35 Ducting System, with 5 m (16.4 ft.) ducting ....P/N 92625013 JEM ZR45 Ducting System, with 5 m (16.4 ft.) ducting ....
  • Page 29 Electronic Equipment), as amended by Directive 2003/108/EC, where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin products. Technical Specifications...
  • Page 30 • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark Tel: +45 8740 0000 • Fax: +45 8740 0010...

This manual is also suitable for:

Jem zr35Jem zr45

Table of Contents