AC power

Read 'Safety information' on page 4 before connecting the fixture to AC mains power.
Electrical installation must be carried out by qualified professionals only.
Lock out power to the entire installation before working on cables and connections.
For protection from dangerous electric shock, the fixture must be grounded (earthed). The
AC power distribution system must be fitted with current overload and ground-fault
(earth-fault) circuit breakers as well as a means to isolate fixtures from power and lock out
power during service.
The Exterior Projection 1000 is supplied in EU and US models. Both models accept AC power at
100-240 V nominal or 277 V nominal at 50 or 60 Hz. Do not connect to power at any other voltage or
frequency.
You can connect the Exterior Projection 1000 to either of the following mains power distribution
systems:
• Single-phase (live, neutral, ground/earth) system.
• Grounded/earthed three-phase four-wire (three phases, neutral, ground/earth) system.
Do not try to connect to a three-phase three-wire (three phases, ground/earth) system.
There is no power on/off switch. Power is applied to an Exterior Projection 1000 fixture as soon as it is
connected to power. Provide a means to disconnect or shut down power to fixtures that is easily
accessible and is located close to the fixtures.
Do not use an external dimming system to supply power to the fixture, as this may cause damage to the
fixture that is not covered by the product warranty.

Connecting to AC mains power

The fixture is supplied with a power cable installed ready for connection. See illustration below:
To connect to a single-phase system or to one phase of a three-phase four-wire system:
1. Lock out power to the installation.
2. Connect the conductors in the power cable to the distribution circuit as follows: a) Connect the
green wire (US models) or yellow/green wire (EU models) to ground (earth). b) Connect the white
wire (US models) or blue wire (EU models) to neutral. c) Connect the black wire (US models) or
brown wire (EU models) to live (one phase of a three-phase system).
3. Check that all installation work is completed and carry out appropriate tests and safety checks
before applying power.