19.3 Advanced
Recording Activity – Advanced
The
The table below describes information presented in the
State
Indicates the current link status as one of the following:
144 of 157 |
Analyzer Recording Activity Menu
tab provides detailed link status, capture, throughput, and error information.
Advanced
No receiver detected.
Electrical idle.
Receiver detected, no SuperSpeed signaling detected.
SuperSpeed signaling detected, receiver synchronized.
Link is unstable, frequent loss of synchronization.
tab for Upstream and Downstream links: