2.3 I Operati ng

Check that there are no tools or other foreign objects in the machine.
The panel that provides access to the technical secti on must be put in place.
Set the valves as follows: valve B wide open, valves A, C, D and E closed.
• An incorrect by-pass setti ng may cause the heat pump to malfuncti on.
Check that the hydraulic correcti ons are correctly ti ghtened and that there are no leaks.
Check that the device is fully stable.
Set the water circulati on running.
Close valve B gradually so that the fi lter pressure is increased by 150g (0.150 bars).
Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
fi ltrati on circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
Connect the power supply to the heat pump.
If the heat pump is on standby, press
is displayed. A 2-minute ti mer will start.
Set the temperature you want ("setpoint" temperature).
Aft er the start-up steps for your heat pump:
Shut down the water circulati on temporarily (by stopping the fi ltrati on or closing valve A or C) to check that you
device stops aft er a few seconds (via the acti vati on of the fl ow rate controller).
Reduce the setpoint temperature to below the water temperature to check that the heat pump stops operati ng.
Switch off the heat pump by pressing and holding
8
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve (opti onal)
: water exit adjustment valve (opti onal)
for 3 seconds; the splash screen appears for 4 seconds then the home screen
for 3 seconds and check that it stops
.