I Additi Onal Menus - Zodiac ZS500 Instructions For Installation And Use Manual

Table of Contents

Advertisement

Display
Error 12
ST5 sensor error
compressor discharge
sensor
Error 13
ST4 sensor fault fl uid line
sensor
Error 14
ST1 sensor fault water
intake sensor

4.3 I Additi onal menus

To access the menu, press
To browse the menus and modify the values, press
To validate a selecti on, press
To go back in the menus, press
Values provided for informati on purposes, factory setti ngs
14
Possible causes
Sensor is faulty or offl ine (J13
connector)
Sensor is faulty or offl ine (J16
connector)
Sensor is faulty or offl ine (J46
connector)
.
or
.
(only accessible to professionals)
Only accessible to professionals
Soluti ons
Reconnect or change the sensor Press
Reconnect or change the sensor Press
Reconnect or change the sensor Press
Water temperature on intake
Air temperature
Defrost sensor
Fluid line sensor
Compressor discharge temperature
Compressor operati ng speed
Venti lator operati ng speed
Opening of electronic valve
Temperature set point
Hysteresis to switch to cooling mode in
relati on to the setpoint
Calibrati on of the ST1 water intake sensor
Calibrati on of the ST2 air intake sensor
Cooling mode acti vati on
Fixed operati ng hours counter
Counter with operati ng hours reset
Acti vati on of conti nuous screen backlighti ng
Acti vati on of heati ng priority mode
"OFF" operati on of the fi ltrati on pump (if P50
= 3)
"ON" operati on of the fi ltrati on pump (if P50
= 3)
H0430700.E - EN - 2016-01
Resetti ng

Advertisement

Table of Contents
loading

Table of Contents