1.3 I Electricity supply connecti ons

• Do not disconnect the electricity supply when the device is running. If the electric power
supply is interrupted, wait a minute before restoring the power.
• Means for disconnecti on from the supply mains having a contact separati on in all poles that
provide full disconnecti on under overvoltage category III, must be incorporated in the fi xed
wiring in accordance with the wiring rules.
• Incorrectly ti ghtened terminals may cause the terminal unit to heat up and invalidate the
warranty.
• Before any work inside the device, you must cut the electricity supply as there is a risk of
electric shock which may cause material damage, serious injury or even death.
• Only a qualifi ed and experienced technician is authorised to carry out cabling in the equipment
or to replace the supply cable.
x 2 short
screws
Access to the technical compartment
The heat pump's electrical supply must be provided through a protecti on and circuit breaking device (not supplied)
complying with the standards and regulati ons in force in the country where it is installed,
The device is provided for connecti on to a general power supply with a TT and TN.S neutral regime.
Electrical protecti on: by circuit breaker (D curve) (for calibre, see § "5.2 I Technical specifi cati ons"), with a 30 mA
dedicated diff erenti al circuit breaker (circuit breaker or switch).
Additi onal protecti on may be required during installati on to guarantee the II overvoltage category.
The electricity supply must correspond to the voltage indicated on the device's informati on plate.
The electricity supply cable must be insulated against any cutti ng or hot elements that may damage or crush it.
The equipment must be connected to an earth socket.
The electrical connecti on lines must be fi xed.
Use the gland to pass the supply cable into the device.
Used the supply cable (H07RN-F type) adapted for outdoor or buried use (or run the cable into a protecti on duct) with
an external diameter of between 9 and 18mm.
We recommend burying the cable at a depth of 50 cl (85 cm under a road or path) in an electrical duct (red ribbed).
If this buried cable meets another cable or pipe (gas, water, etc.), there must be more than 20 cm between them.
Connect the supply cable to the connecti on terminal unit inside the device. On three phase models, there is no live
order to be respected.
L: live
N: neutral
Single phase terminal unit
H0430700.E - EN - 2016-01
x 6 long
screws
: earth
L1-L2-L3: live
N: neutral
Three-phase terminal unit
x 3 small
screws
: earth