Sony PMW-160 Service Manual page 86

Solid-state memory camcorders
Hide thumbs Also See for PMW-160:
Table of Contents

Advertisement

ID
Intended device
0x25
ExpressCard
0x26
(SlotB)
0x23
LED
0x24
LED
0x30
Torino (video signal
line)
0x31
Torino (audio signal
line)
0x32
4-bit signal line
0x01
Details of diagnosis
Error value
0
-1
-4
-6
Item4 (Audio block diagnosis)
The audio block diagnosis tests the following content.
ID
Diagnosis
0x11  
Audio memory area check (in the
CXD9211CGG (Main T-one))
0x12  
FPGA (ANDA) access check
(AU-342 board IC501 A6 pin, A4
pin, A7 pin, A5 pin)
0x13  
DSP-only DPSRAM check
 
0x14  
Serial audio data check in the audio
block
 
0x15  
Serial audio data reception check of
 
IC1700 on the DCP-61 board    
PMW-160/PMW-150/PMW-EX260
Diagnosis
Error value
ExpressCard power
Non-installation "-6" is
switch ON/OFF control
always returned.
ExpressCard overcur-
Non-installation "-6" is
rent detection
always returned.
LED blink check
Refer to "Details of di-
agnosis"
LED blink check
Refer to "Details of di-
agnosis"
Video encoding
Refer to "Details of di-
agnosis"
Audio encoding
Refer to "Details of di-
agnosis"
Transfer data (from
Refer to "Details of di-
Ramiel) check
agnosis"
Command response on-
Normal end "0" is al-
ly
ways returned.
Diagnosis
Normal end
Hardware error detected
Service tool not detected
Non-installation
Error value
-1: Memory read/write comparison
error
-1: Register set value acquisition er-
ror
Other than 0: DPSRAM check error
Error number of failed diagnosis is
displayed as an error value. For error
values, refer to "Error values of di-
agnosis items ID 0x13".
Other than 0: Mismatch between out-
put data and input data
Error number of failed diagnosis is
displayed as an error value. For error
values, refer to "Error values of di-
agnosis items ID 0x14".
Other than 0: Mismatch between out-
put data and input data
Error number of failed diagnosis is
displayed as an error value. For error
values, refer to "Error values of di-
agnosis items ID 0x15".
Type1/2
Note
1
Startup must be com-
pleted
1
Startup must be com-
pleted
1
Startup must be com-
pleted
1
Startup must be com-
pleted
1
Startup must be com-
pleted
1
Startup must be com-
pleted
1
Startup must be com-
pleted
2
Startup must be com-
pleted
Type1/2
Note
1, 2  
1, 2  
1, 2    
1, 2    
This diagnosis using an
internal microphone
may fail depending on
disturbing noise.    
1, 2    
3-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmw-ex260Pmw-150

Table of Contents