Control panel on the global storage cabinet
4.2 Control panel on the global storage cabinet
The control panel is connected to the service processor in global storage. The physical
structure of the control panel is illustrated in the following diagram:
POWER
COMPLETE
Figure 7: Control panel on the global storage cabinet
The functions of the indicators and control elements on the control panel are described
below.
4.2.1 Function of the indicators
STATUS
The STATUS indicator is an LCD display and can show alphanumeric characters. The
codes change when global storage and the IMPL are switched on. No P codes should
be displayed if POWER ON has been executed without errors. If this is not the case, this
indicates a malfunction and you should contact the service department.
18
STATUS
LCD BACK LIGHT
SSU
CHECK
CANCEL/
ALARM STOP
Controls and indicators
BATTERY STATUS
BBON
BS
BI
DI
DS
BE
BF
U41161-J-Z126-1-76