Fujitsu S140 User Manual page 19

Table of Contents

Advertisement

Controls and indicators
The information is shown on the LCD display in the following format:
Figure 8: LC display in the control panel of the global storage cabinet
Meanings:
Line
Line 1
Line 2
U41161-J-Z126-1-76
STATUS
CCCCC
CC C CCCC
FFFFFFFFFFFFFFFF
SSU-0
CM
SSU-1
CE
FFFFFFFFFFFFFFFF
Display field
Display
SSU-No.
SSU-n
Maintenance
none
mode
CE
CM
Test mode
none
T
SSU status
Pnnn
Bnnn
CHK
CNCT
Flag Code
none
FFFFFFFFFFFFFFFF
Control panel on the global storage cabinet
Line 1
Line 2
T Pnnn
Bnnn
Displays in line 1
CHK
CNCT
Displays in line 2
Meaning
SSU number (n = 0/1)
User mode
Maintenance mode
Hot system maintenance mode
Normal mode
Test mode = maintenance mode
(together with CE display)
P000: SSU switched off, battery not active
P001: SSU switched off, battery active
P002 to P599: P codes during the switching
on and initialization phase as well as when
switching off:
nnn shows the time in hours since the backup
battery became active after the network
failure.
SSU in check stop state
SSU connected to a cluster
Normal state
Message or error code:
this display is for the purposes of the service
department.