Pen Parameters; Minimum Output Pulse; Overflow - Datalogic TC1100 Reference Manual

Hide thumbs Also See for TC1100:
Table of Contents

Advertisement

REFERENCES
5.2

PEN PARAMETERS

5.2.1

Minimum Output Pulse

This parameter sets the duration of the output pulse corresponding to the narrowest
element in the barcode. In this way the code resolution is controlled by the signal
sent to the decoder, independently of the physical resolution of the code read.
The shortest pulse (200 µs) corresponds to a high resolution code emulation and
therefore a shorter transfer speed to the decoder (for decoders able to work on high
resolution codes). Likewise, longer pulses correspond to low resolution code
emulation and therefore a longer transfer time to the decoder.
5.2.2

Overflow

This parameter generates a white space before the first bar and after the last bar of
the code. The selections are as follows:
narrow
= space 10 times the minimum output pulse.
medium
= space 20 times the minimum output pulse.
wide
= space 30 times the minimum output pulse.
5
105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents