Connecting to
the line
This is the value limit for a good attenuation result. It is
configured at the STU-R using the EOC. If the attenuation
goes higher than this number, an alarm is generated.
4 Select Margin Thresh., and then enter the margin
threshold.
This is the value limit for a good SNR margin result. It is
configured at the STU-R using the EOC. If the margin falls
below this number, an alarm is generated.
5 Select Loopback Timeout, and then enter the loopback
timeout time.
This is the amount of time, in minutes, that the loopback
will be maintained before dropping.
The CO parameters are set.
After setting the test parameters, you can connect to the line.
To connect to the line
1 Connect one end of the test cable to the 8-pin jack on the
right-hand side of the HST-3000.
2 Connect the other end of the cable to the STU-R.
The test leads are connected.
HST-3000 G.SHDSL Testing User's Guide
Chapter 2 G.SHDSL Testing
Emulating a G.SHDSL STU-C
Modem
41