5.1.3 Keypad operation error description
Display
Error
Er1
Key operation
error
Parameter
Er2
setting error
Modification of
parameter is not
Er5
allowed during
communication
Communication
Er6
failure
Incorrect
Er7
parameter
settings
EP1
Parameter set
error, Copy Unit
failure
Parameters do
EP2
not match
Cause
1. Press▲ or ▼ keys when
A01 > 0 or in speed
operation.
2. Attempt to modify
parameters, which can not
be modified during Run
(see parameter list).
1. A02 is in ranges of
b20±b22 or b21±b22
2. A02 < A03
1. Control command given
when communications are
disabled
2. Attempt to modify b77 ~
b81 during communication.
1. Incorrect cabling.
2. Incorrect settings of
communication parameters.
3. Check sum error.
4. Incorrect communication
program.
1. Attempt to modify b89
2. Voltage and current
detection circuits work
abnormally.
1. b94 = 1,2. Cannot connect
with Copy Unit.
2. Copy Unit failure.
3. The voltage and capacity
parameter of Copy Unit &
the inverter are different.
Copy the parameter to
inverter to verify the
parameter is not match.
5-5
Chapter 5 Trouble shooting and maintenance
1. ▲ or ▼ keys can be used
to modify frequencies only
when A01 = 0.
2. Modify them after stop.
1. Change A02 value
2. Make A02 > A03
Set up parameters before
communicating.
1. Check connections.
2. Check b77 ~ b81
Reset inverter.
If not possible
Contact your supplier
1.Modify b94
3. Change Copy Unit
4. Copy the same inverter
parameter for voltage and
capacity, then input.
1. Change Copy Unit
2. The voltage and capacity
parameter of Copy Unit
are different
Remedy