3.4.2 General Specifications

Output Frequency range 0~200Hz
Starting torque
Speed Control Range
Speed Control
accuracy
Setting resolution ※1 Digital: 0.1Hz(0~99.9Hz)/1Hz(100~200Hz); analog: 0.06Hz/ 60Hz
Keypad setting
Display / Indication
External signal setting •External variable resistor / 0-10V/ 4-20mA
Frequency limit
functions
Carrier frequency
V/F pattern
Acc/dec control
Multi-func. analog O/P 6 functions (refer to b53 description)
Multi-func. digital I/P's 19 functions (refer to b35~b38 description)
Multi-funct. relay O/P 16 functions (refer to b55 description)
DO (relay output)
DI (digital inputs)
AI (analog input)
Other functions
Communication control
Operation temperature
Storage temperature
Humidity
Vibration immunity
EMC ※2
LVD
Enclosure
Safety Class
Chapter 3 Environment description and installation
100% / 3Hz (Vector mode)
1:50(Vector mode)
±0.5% (Vector mode)
Set directly with▲▼ keys or the potentiometer VR on the keypad
7 segment*3. Displays frequency / DC voltage / output voltage /
output current / inverter parameters / alarm log /software version /
PID feedback control
•Performs up/down control (Motorized Pot.) with multi-function
programmable inputs on the terminal base.
Possible to set Upper and Lower frequency limits, and two-stage
skip-frequencies.
4~16KHz (default 10KHz, above 10KHz with de-rating)
Select 6 fixed patterns 50Hz/60Hz or 1 user programmable pattern
Two independent sets of accel / decel ramps (0.1~999s)
1* Relay output as standard SPST.---- selectable as multi-function
output. 1* optional external multi-function output (open-collector
transistor 24V, 600mA)
Selectable NPN/PNP: 4 inputs (S1~S4) as standard;2 expansion
inputs (S5~S6) available on option card.
Set speed command and PID feedback signal (speed, PID, 4~20mA
/ 0~10V) or MFIT S7 [MFIT = multi-function input terminal]
Instantaneous power loss restart, Speed search, auto-restart, DC
brake, torque boost, 2 / 3wire control and PID control.
•RS485 Option card:Modbus RTU/ASCII modes, 4800~38400
bps, max. 254 stations
•PC/PDA software
-10~50°C (inside enclosure) IP20 ; -10~40 IP65
-20~60°C
0 – 95% RH (non condensing)
2
1G (9.8m/s
)
P
P
Built-in: First Environment, Unrestricted Distribution (Class B).
External: First Environment, Restricted Distribution (Class A).
In accordance with EN61800-3
Conforming to EN50178
IP20
UL508C
3-14