IMO iDrive Instruction Manual page 25

Ac micro-inverters for small 3-phase induction motors 100v series, 1-ph / 0.2 – 0.75kw 200v series, 1-ph & 3-ph / 0.2 – 2.2kw 400v series, 3-ph / 0.75 – 2.2kw
Table of Contents

Advertisement

Over load protection Inverter rated current 150%/1min
International
conformity
Over-voltage trip
Under-voltage trip
Instantaneous
power-loss restart
Stall prevention
Output terminal
short circuit
Other faults
Other function
The setting resolution above 100Hz is 1Hz when set by keypad, and 0.01Hz when set using
※1
:
serial communication from computer (PC) or programmable controller (PLC).
Non-standard, un-filtered iDrive model numbers EDX-020-21 to EDX-075-21, and EDX-075-
※2:
43 to EDX-220-43 fitted with optional external filter are in accordance with EN61800-3 First
Environment; Restricted Distribution when carrier frequency is set at
Non-standard, un-filtered iDrive model numbers EDX-150-21 and EDX-220-21, fitted with
optional external filter are in accordance with EN61800-3 First Environment; Unrestricted
Distribution when carrier frequency is set at
Standard, filtered iDrive model numbers EDX-020-21-E to EDX-075-21-E, are in accordance
with EN61800-3 First Environment; Unrestricted Distribution when carrier frequency is set at
1 0KHz or less
U
Model numbers EDX-150-21-E and EDX-220-21-E are in accordance with EN61800-3 First
Environment; Unrestricted Distribution when carrier frequency is set at
IP65 iDrive models EDX-020-21-E-N4(S) to EDX-220-21-E-N4(S) and EDX-075-43-E-N4(S)
to EDX-220-43-E-N4(S) are in accordance with EN61800-3 First Environment; Restricted
Distribution when carrier frequency is set at
UL/cUL/CE
200V Class: DC voltage >400V. 400V Class: DC voltage >800V
200V Class: DC voltage <190V. 400 Class: DC voltage <380V
Set to enable or disable
ACC/DEC/ Operation stall prevention and stall prevention level.
Electronic circuit protection
Electronic circuit protection
Over-current, over-voltage, under-voltage, overload, instantaneous power-loss
restart, ACC/DEC / RUN stall prevention, output terminal short circuit,
grounding error, reverse block, direct start at power on and fault reset limit.
.
U
Chapter 3 Environment description and installation
1 0KHz or less
.
U
U
1 0KHz or less
.
U
U
3-15
1 0KHz or less
.
U
U
6 KHz or less
.
U
U