Readout on VAS 5051
- No communication
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Readout on VAS 5051
01336
Group convenience system data bus
- Defective
- In one-wire operating mode
Readout on VAS 5051
01402
Data wire from navigation
- Implausible signal
65535
Control unit defective
Electrical system Self-diagnosis 02.99 ➤ - Edition 05.2002
Possible cause of trouble
- CAN bus fault
- Open circuit in wiring or short
- Wiring damage
- "1" not displayed in measured val‐
ue block 125 for engine control unit
=>Page
27
- Dash panel insert adaption not
performed correctly
- Automatic parking system control
unit -J446 defective
Possible cause of trouble
- CAN bus fault
- Open circuit in wiring or short at
control unit in convenience system
data bus
- "1" not displayed in measured val‐
ue blocks 125 to 131 for control unit
with CAN capability =>Page
- Adaption to dash panel insert not
performed correctly
- Data bus working only on one wire - Check data exchange => Page
Possible cause of trouble
- Open circuit in clock, enable or data
wire
- Problem with interface between navi‐
gation system and dash panel insert
- Fault caused by electromagnetic inter‐
ference in or outside vehicle
- Dash panel insert defective
Audi A8 1994 ➤
Remedy
- Use current flow diagram to per‐
form fault-finding
=> Current Flow Diagrams, Electri‐
cal Fault-finding and Fitting Loca‐
tions binder
- Select adaption channel 60 and
enter correct adaption value
=>Page
62
- Replace automatic parking sys‐
tem control unit
=> Electrical System; Repair
Group 94; Servicing automatic
parking system; Removing and in‐
stalling automatic parking system
control unit -J446
Remedy
- Use current flow diagram to per‐
form fault-finding
=> Current Flow Diagrams, Electri‐
cal Fault-finding and Fitting Loca‐
tions binder
- Select adaption channel 61 and
enter correct adaption value =>
27
Page
63
69
Use current flow diagram to per‐
form fault-finding
=> Current Flow Diagrams, Electri‐
cal Fault-finding and Fitting Loca‐
tions binder
Remedy
- Check data wires for damage
- Check causes of electromagnetic inter‐
ference
=> Radio, Telephone, Navigation; Repair
Group 91; Navigation System Navigation
System
- Replace dash panel insert
=> Electrical System; Repair Group 90;
Dash panel insert Dash panel insert