Fault Table - Audi A8 1994 Service Manual

Hide thumbs Also See for A8 1994:
Table of Contents

Advertisement

- Fault code
- Fault location
- Type of fault
A - Faults detected:
-
Print out information on screen or self-diagnosis log.
-
Terminate function "02 - Interrogate fault memory" by touching◂key.
-> Readout on VAS 5051:
-
Eliminate fault(s) in line with fault table => Page
-
Select diagnostic function "02 - Interrogate fault memory" again in list and erase fault memory => Page
128
.
-
Select diagnostic function "06 - End output" in list => Page
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
B - No fault detected:
-
Select diagnostic function "06 - End output" in list => Page

4.5 - Fault table

Notes:
◆ Faults occurring in monitored sensors or components are stored in fault memory together with an indication
of the type of fault.
◆ The fault table is arranged according to the 5-digit fault codes on the left.
◆ All static and sporadic faults are stored in the fault memory:
A fault is recognised as being static if it is present for at least 2 seconds. If a fault is then no longer present,
it is stored as being sporadic and "sporadic" also appears on display.
◆ After switching on ignition, all faults present are set to sporadic and only stored as being static if they are
still present after checking.
◆ Sporadic faults are erased if they do not re-occur in the course of 50 driving cycles (ignition on for at least
5 minutes, vehicle speed greater than 30 km/h).
◆ Do not immediately replace components indicated as being defective by VAS 5051, but rather: Start by
checking wiring and connectors to these components in line with current flow diagram. Also use current flow
diagram to check earth connections. This is particularly important if faults are output as being "sporadic".
◆ On completion of repair work, fault memory is to be interrogated again and erased.
Readout on VAS 5051 Possible cause of trouble
00532
Supply voltage
- Signal too low
Electrical system Self-diagnosis 02.99 ➤ - Edition 05.2002
- Open circuit in wiring or short in power
supply
121
.
129
.
129
.
Remedy
- Use current flow diagram to perform fault-
finding
=> Current Flow Diagrams, Electrical Fault-
finding and Fitting Locations binder