Sequence of operations
After fault memory interrogation:
-> Readout on VAS 5051:
-
From list -1- select diagnostic function "05 - Erase fault memory".
-> Readout on VAS 5051:
1 -
- No readout (prior to erasing)
Or
-Fault memory erased
Note:
If the following message appears in display zone -1-: "Fault memory not yet interrogated", this means that
sequence of operations has not been precisely observed. Fault memory cannot be erased until it has been
interrogated.
2 -
Note:
Is function to be implemented?
Note: Data will be erased!
-
Touch "OK" key on display -2-.
-
Terminate function "05 - Erase fault memory" by touching ◂ key.
-
Interrogate fault memory again after performing repair work.
Note:
This erases faults stored during fault elimination e.g. on account of connectors being unplugged.