 Setting the IP addresses
automatically (auto IP setting)
When "Auto IP setting" is initiated, the IP addresses are set
automatically for the remote cameras and the switcher which
are connected within the same subnet.
The IP addresses can be set for up to 100 remote cameras
and one switcher.
[Remote camera settings]
The unit sets the IP addresses for the remote cameras
that have been detected by associating them with camera
numbers whose connection setting is set to "NoAsign".
Connection settings:
On the [SYSTEM] menu, select [CAMERA CTL], and
then display items [CAM1] to [CAM100].
Setting or changing IP addresses:
On the [SYSTEM] menu, select [CAM IP ADR], and
then display items [CAM1] to [CAM100].
Example:
 Remote cameras A, B, and C are detected.
 In [CAMERA CTL], items [CAM1] to [CAM3] are all
set to "NoAsign".
 In [CAM IP ADR], the IP addresses of items
[CAM1] to [CAM3] range from 192.168.000.010 to
192.168.000.012.
In the above example, the IP addresses for the remote
cameras are set as follows:
Remote camera A: 192.168.000.010
Remote camera B: 192.168.000.011
Remote camera C: 192.168.000.012
 Subnet mask, default gateway, and port number
settings are the same as those for the unit.
 The connection setting for camera numbers that
have been set once with "Auto IP setting" becomes
"Network".
These camera numbers will be excluded as targets of
"Auto IP setting" the next time that "Auto IP setting" is
performed.
However, if the IP address for a camera number that
has been set with "Auto IP setting" is changed, or if
a camera number's connection setting is changed
to "NoAsign" or "Serial", the corresponding camera
numbers will be targeted in the next "Auto IP setting"
operation.
 If the IP address for a detected remote camera
matches the IP address set for a camera number (a
camera number with a connection setting other than
"Serial"), the IP address setting for the remote camera
will be used as is. If the IP address for a remote
camera is set once and then changed so that it differs
from the IP address set for the camera number, the
remote camera IP address is set again to the camera
number IP address.
[Switcher settings]
On the [SYSTEM] menu, in [SW CTL], if the [SW] item is
set to [NoAsign], the IP address for the switcher will be
set from the unit.
The IP address set in the [IP:SW] item from [SW IP ADR]
on the [SYSTEM] menu will be set for the switcher.
Note
Duplication in the IP addresses may arise when a
device other than a remote camera or switcher has been
connected within the same subnet.
Connect only devices which are covered by the "Auto IP
setting" within the same subnet.
 When setting the IP addresses for the
first time
The IP addresses are set while the remote cameras,
switcher and unit are at their factory settings.
1
Connect the remote cameras, switcher and
unit to the network within the same subnet.
192.168.000.010
192.168.000.010
192.168.000.010
192.168.000.009
23 (G)
192.168.000.011
192.168.000.010
192.168.000.012
192.168.000.008
192.168.000.008